Added cable schedule naming and general tidying.
This commit is contained in:
parent
97d1f4e58c
commit
0bfc55c880
1 changed files with 41 additions and 7 deletions
|
|
@ -35,7 +35,7 @@ def percentvd(vd,nominal):
|
|||
return percent
|
||||
|
||||
|
||||
def voltage_drop(nominal_voltage, current, conductor_size, material ='cu', num_runs = 1, code = 'CEC'):
|
||||
def voltage_drop(nominal_voltage, current, conductor_size, length,material ='cu', num_runs = 1, code = 'CEC'):
|
||||
|
||||
'''
|
||||
This function will return the drop in voltage and in percent of the supply.
|
||||
|
|
@ -87,7 +87,7 @@ def voltage_drop(nominal_voltage, current, conductor_size, material ='cu', num_r
|
|||
else:
|
||||
return (print("error, choose material as cu or al"))
|
||||
|
||||
voltage = vd(nominal_voltage,current,resistance,num_runs)
|
||||
voltage = vd(current,length,resistance,num_runs)
|
||||
percent = percentvd(voltage,nominal_voltage)
|
||||
|
||||
return [voltage, percent]
|
||||
|
|
@ -149,7 +149,7 @@ def voltage_drop_conductors(voltage,current,distance,v_drop_percent = 0.03,runs
|
|||
with sqlite3.connect("jepl-cable.db") as con:
|
||||
cur = con.cursor()
|
||||
cur.execute('SELECT "Conductor Size" FROM "SW-Spec 25055" WHERE "Conductor Number" = 3 AND "AC Resistance"<?', (resistivity,))
|
||||
conductor = cur.fetchone()[0]
|
||||
conductor = str(cur.fetchone()[0])
|
||||
|
||||
#print(conductor)
|
||||
|
||||
|
|
@ -161,7 +161,7 @@ def voltage_drop_conductors(voltage,current,distance,v_drop_percent = 0.03,runs
|
|||
with sqlite3.connect("jepl-cable.db") as con:
|
||||
cur = con.cursor()
|
||||
cur.execute('SELECT "Conductor Size" FROM "SW-Spec 25051" WHERE "Conductor Number" = 3 AND "AC Resistance"<?', (resistivity,))
|
||||
conductor = cur.fetchone()[0]
|
||||
conductor = str(cur.fetchone()[0])
|
||||
|
||||
#print(conductor)
|
||||
|
||||
|
|
@ -188,7 +188,7 @@ def current_for_lookup(current,max_current):
|
|||
|
||||
return (con_current,num_parallel)
|
||||
|
||||
def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway = True, ambient = 30, max = 500):
|
||||
def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway = True, ambient = 30, max = 500, load_type = None):
|
||||
|
||||
'''
|
||||
The default temp column will be the 75C column as most terminals are rated for this.
|
||||
|
|
@ -197,7 +197,6 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
I still need to incorporate ambient temperature deratings, but that will be a future improvement
|
||||
|
||||
'''
|
||||
|
||||
material = material.upper()
|
||||
code = code.upper()
|
||||
max = str(max)
|
||||
|
|
@ -208,6 +207,8 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
valid_material = ['CU',
|
||||
'AL',
|
||||
]
|
||||
valid_load_type = ['normal','xfmr','xfmrp','xfmrs','motor',None]
|
||||
|
||||
|
||||
#check to make sure that the values are valid
|
||||
if temp not in valid_temp:
|
||||
|
|
@ -216,6 +217,8 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
return print(code + " is not a valid code. The valid codes are "+ str(valid_code))
|
||||
if material not in valid_material:
|
||||
return print(material + " is not a valid material. I should be 'al' or 'cu'.")
|
||||
if load_type not in valid_load_type:
|
||||
return print(load_type + " is not a valid load_type.")
|
||||
|
||||
if temp == 90:
|
||||
conductor_current_index = 3
|
||||
|
|
@ -225,6 +228,13 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
conductor_current_index = 1
|
||||
|
||||
|
||||
'''
|
||||
Per CEC rules 26-256 and 28-106 Transformer and Motor conductors should be sized 125% of the rated current.
|
||||
'''
|
||||
list_125 = ['xfmr','xfmrp','xfmrs', 'motor']
|
||||
if load_type in list_125:
|
||||
current = 1.25 * current
|
||||
|
||||
# select the correct code table
|
||||
if (code == 'CEC') & (material == 'CU') & (raceway == False): # CEC Table 1
|
||||
try:
|
||||
|
|
@ -351,7 +361,7 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
|
||||
else:
|
||||
cur.execute('SELECT size FROM "Table4" WHERE "60" > ? ', (current,))
|
||||
conductor_size = cur.fetchone()[0]
|
||||
conductor_size = str(cur.fetchone()[0])
|
||||
|
||||
#print(conductor_size)
|
||||
|
||||
|
|
@ -367,5 +377,29 @@ def conductor_size(current, temp = 75, material = 'cu', code = 'CEC', raceway =
|
|||
return [conductor_size,num_parallel]
|
||||
|
||||
|
||||
def cable_schedule_naming(conductor_size,conductors,runs = 1,bond='BOND'):
|
||||
'''
|
||||
Converts the conductor size from the above functions to something that can be added to a database/schedule.
|
||||
'''
|
||||
|
||||
|
||||
if conductor_size == '1/0' or conductor_size == '2/0' or conductor_size == '3/0' or conductor_size == '4/0':
|
||||
unit = "AWG"
|
||||
elif int(conductor_size) > 24:
|
||||
unit = 'kcmil'
|
||||
else:
|
||||
unit = 'AWG'
|
||||
|
||||
if bond == 'BOND':
|
||||
bondtext = bond
|
||||
elif int(bond_size) > 24:
|
||||
bondtext = '#' + str(bond) + 'kcmil'
|
||||
else:
|
||||
bondtext = '#' + str(bond) + 'AWG'
|
||||
|
||||
if runs > 1:
|
||||
cable_text = str(runs) + "x " + str(conductors) + "C #" + str(conductor_size) + unit + " + " + bondtext
|
||||
else:
|
||||
cable_text = str(conductors) + "C #" + str(conductor_size) + unit + " + " + bondtext
|
||||
|
||||
return cable_text
|
||||
|
|
|
|||